GTBTRANSFORMERS19C0 59dc6133385187052c36ddc7 False 73 26
OK

Guru Teg Bahadur Metal Works

About

Being an engineering company that to driven by its customers- where customers are not only the responsibility of a single sales department but company-wide undertaking that drives the company’s vision, mission and strategic planning. Success depends when we work towards the customer goal- when finance furnishes right amount of funding, purchasing buys the right materials, production makes the right product in the right time horizon, and a constant R&D is done to make the product better and better. Such interdepartmental harmony can only build not customers but partners.

Latest update

GTB Make all type of transformers.we also make dry type (VPI) transformers. we make compact substation, HT AVR also.
view all updates 1526023660

Products

Automatic Servo Voltage Stabilizer
Automatic Servo Voltage Stabilizer INR 0 INR 0 Product Details: Phase: Three Phase Power: 2000 KVA Input Voltage: 320 V True 1509026888
59f1ec48c1b53d08300770fd
-0%
Automatic Voltage Regulator
Automatic Voltage Regulator INR 0 INR 0 The table below gives approximate quantitative advantages of automatic voltage controller at various fluctuation levels: Comparison between GTB make and Conventional make automatic voltage controller: GTB make Roller Type Regulator: Power consumption is 0.5 to 1.5% depending upon the model input voltage variation. Suitable for continuous 100% duty cycle. Life at full load is 15-20 years. Five years unconditional guarantee. Negligible losses in full boost buck condition. Conventional make with Carbon Brush Regulator: Power consumption is 2 to 7% depending upon the model input voltage variation. Suitable for only 30% to 40% duty cycle. Maximum life is 2-3 years at full load. Normal guarantee for one year. Max. Losses in full boost and buck condition. True 1509027560
59f1eee8587b0e05547341c5
-0%
OLTC Distribution Transformer
OLTC Distribution Transformer INR 0 INR 0 Product Details: Tapping: + 5% to -15% in steps of 1.25% or as per customers requirement. Range of Transformer : Upto 3500 KVA Frequency: 50 ~ 60 Hz On-load tap changer (OLTC) is used with higher capacity transformers where HT side voltage variation is frequent and a nearly constant LT voltage is required. OLTC is coupled with the transformer itself. Multiple tapings from HV winding are brought to the OLTC chamber and connected to fixed contacts. Moving contacts rotates with the help of rotating mechanism usually a Geneva mechanism having a spindle. The spindle can be rotated manually as well as electrically with a motor. The motor is connected in such a way that it can rotate in both the directions such as to rotate the OLTC moving contacts clockwise and anti-clockwise. Two push buttons are fitted on the LCP (low control panel) to rotate the motor and hence the OLTC contacts. This movement of contacts thus controls the output LV voltage of the transformer. So rotating of the OLTC contacts with the spindle or push button in this way is the manual process. In case this process of rotating the OLTC contacts and hence controlling the LV side voltage is to be done automatically then an RTCC (remote tap changer controller) is installed with the transformer hot panel. The RTCC panel which has sensors which sense the output voltage and accordingly sends the signal to LCP and LCP in turns rotates the motor as per signal received from the RTCC. Other Details: Vector Group: Unless or otherwise specified, the transformers will be connected as per Vector Group reference Dyn 11 in accordance with International practice. Core: The core used is the best quality cold rolled grain oriented and laser processed silicon steel sheet. They provide low iron loss, low noise, and compact size and have the best performance for high-efficiency transformers. Windings: We use high-quality conductor of copper aluminum in our products. Round or rectangular copper/aluminum wires ribbed with thermally upgraded insulting paper are applied in oil immersed transformers. The winding has a compact size, excellent heat transmission, low load loss, highlighting impulse resistivity and outstanding anti-short- circuit strength. Insulation: Our oil-immersed transformers are insulated by electrical grade insulated press board and thermally upgrade insulating Kraft paper. Oil: Dehydrated EHV-Grade transformers oil as per IS 355 (1993) with latest amendments is used for proper insulation and cooling after testing for all the parameters viz a viz resistivity, tan delta, BDV, neutralization, flash point etc. Bushings: HV/LV Bushings: The quality porcelain bushings are used on the high voltage terminals/low voltage terminals. Optional bushing wells, inserts, and elbows are available upon request. High voltage cables are inserted directly and show no live parts outside. Accessories: The accessories include an oil filling hole, oil drain valve, safety valve, standard thermometer, oil level gauge, skid wheel, jacking pad, breather, earthing terminal Optional Accessories: Buchholz relay, cooling fan, HV LV cable box, cable duct, bus bar duct, dial-type thermometer, oil level gauge, on-load type tap changer, protective fuse and lightening arresters are available upon customer’s request at extra cost. OLTC Transformers are used in: Chemical plant, Bottling plant. Paper mills, Sugar Mills, Rolling Mills, Steel Mills. Industries which rely heavily on automation, where electronic cards, PLC, and VFDs are used in operations and actuation. True 1509026320
59f1ea10a0fd000a3012e2ea
-0%
Industrial Isolation Transformer
Industrial Isolation Transformer INR 0 INR 0 Product Details: Input Voltage: 11 / 22 / 33 KV Power: 2500 KVA Frequency: 50 Hz True 1509027060
59f1ecf4bdca770b08d62bd3
-0%
Isolation Transformer
Isolation Transformer INR 0 INR 0 Product Details: Input Voltage: 11 KV Power: 80 KVA Frequency: 50 HZ True 1509027121
59f1ed31bdca770b08d62bf6
-0%
Compact Substation
Compact Substation INR 0 INR 0 Product Details: Phase: Three Phase Frequency: 50 / 60 Hz Rated Current: 630 A GTB’s Compact Substation is used for feeding power from high voltage to low voltage in open cast mines, construction sites, metro cities etc. The substation is compact in size, suitable for frequent shifting and for use in indoor/outdoor locations. The substation is installed and mounted on skid frame or wheels or channels and is provided with lifting hooks. Features: Easy to operate, safe. Compact portable ready to install Designed for better cooling Transformer dry type or oil cooled Low maintenance Customer made design Superior aesthetics Suitable for all weathers Design Combination: HT Compartment: Ring Main Unit Vacuum Circuit Breaker Load Break Switches Transformer Compartment: Oil Cooled Transformer or Cast VPI Dry Type Low Losses Design Tap Changer LT Compartment: Air circuit breaker Molded case circuit breaker Fuse units Fuses True 1509027475
59f1ee93ffe6360ac4521d26
-0%
Oil Filled Transformer
Oil Filled Transformer INR 0 INR 0 Product Details: Power (VA): 1000 KVA Phase: Three Phase Frequency: 50 or 60 Hz True 1509027253
59f1edb5587b0e055473411a
-0%
Step Down Transformer
Step Down Transformer INR 0 INR 0 Product Details: Output Voltage: 433 KV Input Voltage: 32 KV Power: 2000 W Phase: Three Phase Frequency: 50 ~ 60 Hz Brand: GTB True 1509027313
59f1edf13f035b0b20a8706b
-0%
View All

Our timings

[IS_BIZ_OPEN] Mon: 9:30AM  -  6:00PM
[IS_BIZ_OPEN] Tue: 9:30AM  -  6:00PM
[IS_BIZ_OPEN] Wed: 9:30AM  -  6:00PM
[IS_BIZ_OPEN] Thu: 9:30AM  -  6:00PM
[IS_BIZ_OPEN] Fri: 9:30AM  -  6:00PM
[IS_BIZ_OPEN] Sat: 9:30AM  -  6:00PM
[IS_BIZ_OPEN] Sun: Closed  -  Closed

Contact

GTB transformers
+91 8030905872  or   or   
Please keep or 0 before the
number when you dial.
Share Tweet
False

SUBSCRIBE

More

22.7195687 75.8577258 Guru Teg Bahadur Metal Works GTB transformers
59dc6133385187052c36ddc7GTBTRANSFORMERS19C057c3c1a65d64370d7cf4eb17